Tranzitii FRIALEN

MUN V2A

Tranzitii Electrofuziune PE-HD/V2A cu filet exterior

Transition Fittings HD-PE/Stainless steel with male thread
Compact transition fitting. HD-PE end with exposed heating coils for optimal heat transfer, large insertion depth, wide fusion zone plus cold zones at the end and in the transition area to prevent the flow of molten material for use without holding devices. Stainless steel end permanently anchored in the HD-PE. Self sealing patented sealing geometry without elastomer seal. For use in water systems.

Other thread sizes on request

PE 100 SDR 11

Maximum working pressure 16 bar (water)

SKU d BX PU D R L t z h B Weight kg
1 616516 40 20 800 58 1″ 123 46 75 30 70 0,460
612727 40 20 800 58 1 1/2″ 127 46 78 30 70 0,495
612726 50 15 600 70 1 1/2″ 137 53 84 30 80 0,600
612705 63 10 400 84 1 1/2″ 137 53 84 35 94 0,865
612899 63 10 400 84 2″ 142 53 89 35 94 0,910
1 minimum order quantity = 1 packaging unit

Other thread sizes on request

FRIALEN safety fittings can be fused to pipes SDR11 – SDR 17.6, minimum wall thickness s min ≥ 3 mm. Other SDR-stages on request. Please observe the marking directly at the product, which is mandatory.

DVGW-Registration Nos. DV-7501AU2256 and DV-7501AU2257

Areas of Application

FRIALEN-Transition Fittings MUN-V2A are threaded joints as an adaptor from a metal pipe with internal thread to a HD-PE pipe. Joint on the part of HDPE by FRIALEN-Coupler. The threaded joint is made of stainless steel (Material St. 1.4305 / X8CrNiS18-9).

Assembly Instructions

During assembly, only a spanner applied to the provided metal hexagon must be used to screw the component into its metal counterpart. The fusion of the HD-PE side takes place by FRIALEN-fusing – leakproof and longitudinally strong.

The installation of the stainless steel and the HD-PE side has to be prepared according to the general installation instructions (see ”Transition Fittings with threaded connection” in ”Assembly Instructions” for ”FRIALEN-Safety Fittings for house connections and distribution pipes up to d 225”). This involves removing the oxide skin and cleaning the pipe ends.

Good reasons for using the FRIALEN-Transition Fittings MUN-V2A:

  • Compact construction
  • HD-PE side with exposed heating element for optimal heat transfer
  • Cold zones at the end to prevent the flow of molten material
  • No holding clamps required
  • Large insertion depth, extra wide fusion zones
  • Stainless steel end permanently anchored in the HD-PE and will not distort
  • Self sealing patented sealing geometry without elastomer seal
  • Additional barcode for tracing back the underground fitting (Traceability-Coding)
  • Threaded joint made of stainless steel (St. 1.4305) = resistant to corrosion
  • Suitable for usage in high humidity environment or in industrial area