Selectează o Pagină

Tranzitii FRIALEN

USTM

Tranzitii PE-HD/Alama cu filet interior

Transition Fittings HD-PE/Steel with female thread
Compact transition fitting. HD-PE end with exposed heating coils for optimal heat transfer, large insertion depth, wide fusion zone plus cold zones at the end and in the transition area to prevent the flow of molten material for use without holding devices. Steel end permanently anchored in the HD-PE. Self sealing patented sealing geometry without elastomer seal. For use in gas systems.

Other thread sizes on request

PE 100 SDR 11

Maximum working pressure 5 bar (gas)

SKU d Rp BX PU D L t z h B Weight kg
612570 32 1″ 20 1080 47 112 42 49 24 61 0,340
612572 40 1 1/4″ 20 800 58 121 46 53 30 70 0,500
612574 50 1 1/2″ 15 600 70 136 53 60 30 80 0,650
612576 63 2″ 10 400 84 141 53 61 35 94 1,010

Other thread sizes on request

FRIALEN safety fittings can be fused to pipes SDR11 – SDR 17.6, minimum wall thickness s min ≥ 3 mm. Other SDR-stages on request. Please observe the marking directly at the product, which is mandatory. DVGW-Registration No. DV-7501AU2256

Areas of Application

FRIALEN-Transition Fittings USTM are threaded joints as an adaptor from a metal pipe with external thread to a HD-PE pipe. Joint on the part of HD-PE by FRIALEN-Coupler.

Assembly Instructions

The threaded component must be held with a spanner to prevent it twisting in the HD-PE component. The fusion of the HD-PE side takes place by FRIALEN-fusing – leakproof and longitudinally strong.

The installation of the steel and the HD-PE side has to be prepared according to the general installation instructions (see ”Transition Fittings with threaded connection” in ”Assembly Instructions” for ”FRIALEN-Safety Fittings for house connections and distribution pipes up to d 225”). This involves removing the oxide skin and cleaning the pipe ends.

Good reasons for using the FRIALEN-USTM:

  • Compact construction
  • HD-PE side with exposed heating element for optimal heat transfer
  • Cold zones at the end to prevent the flow of molten material
  • No holding clamps required
  • Large insertion depth, extra wide fusion zones
  • Steel end permanently anchored in the HD-PE and will not distort
  • Self sealing patented sealing geometry without elastomer seal
  • Additional barcode for tracing back the fitting (Traceability-Coding)